ICCAS OpenIR
New cryogenic apparatus for FT-IR spectroscopic studies
Kang, N; Xu, YZ; Ferraro, JR; Li, WH; Weng, SF; Xu, DF; Wu, JG; Soloway, RD; Xu, GX
2001-05-01
Source PublicationAPPLIED SPECTROSCOPY
ISSN0003-7028
Volume55Issue:5Pages:643-646
AbstractCryogenic Fourier transform infrared (PT-IR) spectroscopy, being an effective technique in improving the spectral resolution and signal-to-noise ratio, is utilized in our group. However, we have found the traditional cryogenic apparatus inconvenient in the following aspects: (1) The system does not work very well in preventing moisture/frost from condensing on the salt windows or samples. (2) The indirect way of cooling using a metal cold finger limits the efficiency of the system, We have designed a new cryogenic apparatus. The apparatus is composed of a cooling stage and a measuring stage, In the cooling stage, the sample is directly immersed in Liquid nitrogen, In the measuring stage, the sample is lifted just above the surface of liquid nitrogen, and the FT-IR spectrum is recorded. The dry cold nitrogen gas evaporated from liquid nitrogen forms a protective layer surrounding the sample and prevents moisture from condensing on the sample. Thus, neither vacuum nor salt windows are needed in cryogenic spectroscopic experiments using this method. The experimental results show that our method is effective in cryogenic FT-IR spectroscopic studies.
KeywordFt-ir Spectroscopy Cryogenic Apparatus
Indexed BySCI
Language英语
WOS IDWOS:000169091900017
PublisherSOC APPLIED SPECTROSCOPY
Citation statistics
Cited Times:3[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.iccas.ac.cn/handle/121111/77258
Collection中国科学院化学研究所
Corresponding AuthorWu, JG
Affiliation1.Peking Univ Univ Hong Kong Joint Lab Rare Earth M, Dept Chem, State Key Lab Rare Earth Mat Chem & Applicat, Beijing 100871, Peoples R China
2.Argonne Natl Lab, Div Chem, Argonne, IL 60439 USA
3.Chinese Acad Sci, Inst Chem, Beijing 100080, Peoples R China
4.Univ Texas, Med Branch, Galveston, TX 77550 USA
Recommended Citation
GB/T 7714
Kang, N,Xu, YZ,Ferraro, JR,et al. New cryogenic apparatus for FT-IR spectroscopic studies[J]. APPLIED SPECTROSCOPY,2001,55(5):643-646.
APA Kang, N.,Xu, YZ.,Ferraro, JR.,Li, WH.,Weng, SF.,...&Xu, GX.(2001).New cryogenic apparatus for FT-IR spectroscopic studies.APPLIED SPECTROSCOPY,55(5),643-646.
MLA Kang, N,et al."New cryogenic apparatus for FT-IR spectroscopic studies".APPLIED SPECTROSCOPY 55.5(2001):643-646.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Kang, N]'s Articles
[Xu, YZ]'s Articles
[Ferraro, JR]'s Articles
Baidu academic
Similar articles in Baidu academic
[Kang, N]'s Articles
[Xu, YZ]'s Articles
[Ferraro, JR]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Kang, N]'s Articles
[Xu, YZ]'s Articles
[Ferraro, JR]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.